Energize Denver Article XIV Compliance Reference
Authoritative reference for Denver's High-Performance Existing Buildings Program (Article XIV) compliance requirements, pathways, deadlines, and penalties.
When to Use This Skill
Invoke this skill when working with:
- Energize Denver compliance questions - Requirements, deadlines, penalties
- Denver Article XIV regulations - Building performance policy details
- MAI buildings - Manufacturing, Agricultural, Industrial compliance pathways
- Performance targets - Baseline calculations, interim/final targets (2024/2027/2030)
- Compliance pathways - Whole-building EUI, production efficiency, prescriptive paths
- Benchmarking requirements - Annual submission rules, Energy Star Portfolio Manager
- Penalty calculations - Rates, shortfall calculations, enforcement
- Timeline extensions - Application process, valid reasons, requirements
- Alternate compliance options - Timing adjustments, target modifications
What This Skill Provides
Regulatory Knowledge:
- Complete Article XIV requirements by building size and type
- MAI production efficiency pathway (detailed guidance)
- Performance target calculation methods
- Penalty rates and enforcement procedures
- Deadline and milestone tracking
- Alternate compliance application requirements
Decision Support:
- Pathway selection criteria (EUI vs production efficiency vs prescriptive)
- Compliance vs penalty cost analysis
- Timeline extension eligibility assessment
What This Skill Does NOT Cover
- ❌ Pricing or scoping Energize Denver services → Use writing-proposals skill
- ❌ General proposal development → Use writing-proposals skill
- ❌ Non-Denver building performance programs
- ❌ Technical energy modeling or audit procedures
Quick Reference
Building Categories
25,000+ sf (Non-MAI):
- Annual benchmarking (due June 1)
- Performance targets: 2024, 2027, 2030
- Baseline: Typically 2019 EUI
- Compliance metric: 30% EUI reduction by 2030
25,000+ sf (MAI Buildings):
- Two pathway options: Prescriptive or Performance
- Performance metrics: 30% EUI reduction OR 30% production efficiency OR 52.9 EUI OR ENERGY STAR 75
- First performance year: 2026
- Application deadline: December 31, 2025
5,000-24,999 sf:
- LED lighting OR 20% solar by deadline
- Deadlines: Dec 31, 2025/2026/2027 (by size tier)
Key Deadlines
| Date | Requirement |
|---|
| June 1 (annual) | Benchmarking submission (25k+ sf) |
| December 31, 2025 | MAI ACO application deadline |
| December 31, 2025 | Small buildings 15k-25k sf LED/solar |
| December 31, 2026 | Small buildings 10k-15k sf LED/solar |
| December 31, 2027 | Small buildings 5k-10k sf LED/solar |
| June 1, 2025 | Demonstrate 2024 target compliance |
| June 1, 2028 | Demonstrate 2027 target compliance |
| June 1, 2031 | Demonstrate 2030 target compliance |
Penalty Rates (Updated April 2025)
Standard Commercial Buildings (25,000+ sf):
- $0.15/kBtu - Buildings on standard updated timeline
- $0.23/kBtu - Buildings opted into 2028/2032 timeline
- $0.35/kBtu - Buildings granted timeline extensions
- +$0.10/kBtu surcharge - Extensions requested after target year ends
MAI Buildings: Same rates apply to production efficiency shortfalls
How to Use This Skill
Answer Regulatory Questions
When the user asks about Energize Denver requirements:
-
Identify the question type:
- Building applicability and exclusions?
- Compliance pathway selection?
- Performance target calculation?
- Penalty calculation?
- Deadline or milestone?
- Application requirements?
-
Consult the detailed requirements:
-
Provide specific, actionable answers:
- Cite specific sections and requirements
- Include deadlines, formulas, and rates
- Explain implications and decision criteria
Pathway Selection Guidance
When helping users choose compliance pathways:
For MAI Buildings, evaluate:
- Production growth expectations
- Production metric clarity and measurability
- Availability of historical production data (2018-2022)
- Process load percentage vs HVAC/lighting
- See ./article-xiv-requirements.md → "Production Efficiency Pathway - Detailed Requirements"
For Standard Commercial Buildings, evaluate:
- Current EUI vs performance targets
- Feasibility of operational improvements
- Capital improvement budget
- Renewable energy options
- Timeline flexibility needs
Penalty Calculations
When calculating potential penalties:
- Determine shortfall: Target kBtu reduction - Actual kBtu reduction
- Identify penalty rate: Based on timeline status (see rates above)
- Calculate penalty: Shortfall (kBtu) × Penalty Rate ($/kBtu)
- Consider timeline: Multi-year penalties for ongoing non-compliance
Example from requirements document:
Building on 2028/2032 timeline:
Shortfall: 20,000 kBtu
Rate: $0.23/kBtu
Penalty: $4,600
Timeline Extensions
When users ask about timeline extensions:
Valid Reasons (from Article XIV):
- End-of-life equipment replacement planning
- Major renovations in progress
- Whole-building electrification projects
- District steam system limitations
- Energy service capacity constraints (requires Xcel documentation)
- Innovative projects causing delays
Application Requirements:
- ASHRAE Level II audit
- Detailed compliance plan (CASR template)
- Financing strategy
- Specific measures with timelines
Important: Applying after target year ends triggers +$0.10/kBtu surcharge
See ./article-xiv-requirements.md → "Timeline Extensions for MAI Buildings" (also applicable to standard buildings)
Cross-References to Other Skills
When pricing or scoping Energize Denver services, use the writing-proposals skill:
- ASHRAE Level 1/2/3 audit pricing
- Benchmarking service scoping
- Compliance pathway consulting pricing
- Proposal generation and formatting
Example collaborative workflow:
- User: "Create Energize Denver MAI proposal for print shop"
- energize-denver (this skill): Identify MAI pathway requirements, production efficiency metric selection, Dec 31 deadline
- writing-proposals: Price ASHRAE Level II audit, structure scope of work, generate proposal document
Complete Regulatory Reference
For comprehensive Article XIV details, see:
This file contains:
- Detailed applicability and exclusions
- Complete building category requirements (25k+ sf, 5k-25k sf)
- MAI production efficiency pathway (comprehensive guidance)
- Baseline establishment and target calculations
- Compliance demonstration procedures
- Alternate compliance options and applications
- Enforcement and penalty details
- Timeline extensions and application requirements
- CASR contact information and resources
External Resources
Known Gaps and Limitations
When consulting ./article-xiv-requirements.md, note the "Known Gaps and Limitations" section identifies:
- Pre-approved production metrics by industry (not published by CASR)
- Product mix change handling for production efficiency
- Metric change procedures after ACO approval
- MAI ACO application review timelines
For these questions, recommend direct CASR contact: energizedenver@denvergov.org
Important Notes
This skill provides regulatory guidance only. It does not:
- Price services (use writing-proposals skill)
- Provide detailed engineering analysis
- Substitute for legal counsel
- Replace official CASR guidance
Always verify:
- Current penalty rates with CASR (rates updated April 2025)
- Application deadlines and requirements
- Specific building applicability before providing advice
Data quality matters:
- Production efficiency requires measured data (estimated data not explicitly allowed)
- Weather normalization required for energy data
- Complete calendar year coverage required (no partial-year data)